mvNTo1: Sets the frame
average operating mode.
mvNTo1Sum: Sets the frame
average operating mode.
mvFrameAverageFrameCount 2 10 1 -
Here you specify the frame
count used for the calculation
of the frame average.
Feature Name Min Max Inc Valid Values Documentation
SequencerControl
A category for the
Sequencer Control
features.
SequencerMode - - -
Off,
On
Controls if the sequencer
mechanism is active.
Off: Disables the
sequencer.
On: Enables the
sequencer.
SequencerConfigurationMode - - -
Off,
On
Controls if the sequencer
configuration mode is
active.
Off: Disables the
sequencer configuration
mode.
On: Enables the
sequencer configuration
mode.
SequencerFeatureSelector - - -
ExposureTime,
CounterDuration,
BinningHorizontal,
BinningVertical
Selects which sequencer
features to control.
ExposureTime: Selects
which sequencer
features to control.
CounterDuration: Selects
which sequencer
features to control.
BinningHorizontal:
Selects which sequencer
features to control.
BinningVertical: Selects
which sequencer
features to control.
SequencerFeatureEnable - - -
0,
1
Enables the selected
feature and make it
active in all the
sequencer sets.
SequencerSetStart 0 31 1 - Sets the initial/start
sequencer set, which is
the first set used within a
20 Appendix A.1 Pregius CMOS specific camera / sensor data