ExposureActive: Selects
the source to start the
Counter.
CounterTriggerActivation - - -
RisingEdge,
FallingEdge,
AnyEdge,
LevelHigh,
LevelLow
Selects the activation
mode of the trigger to
start the Counter.
RisingEdge: Starts
counting on the Rising
Edge of the selected
trigger signal.
FallingEdge: Starts
counting on the Falling
Edge of the selected
trigger signal.
AnyEdge: Starts counting
on the Falling or rising
Edge of the selected
trigger signal.
LevelHigh: Counts as
long as the selected
trigger signal level is
High.
LevelLow: Counts as
long as the selected
trigger signal level is
Low.
CounterDuration 0 UINT_MAX 1 -
Sets the duration (or
number of events) before
the CounterEnd event is
generated.
CounterValue 0 UINT_MAX 1 -
Reads or writes the
current value of the
selected Counter.
CounterValueAtReset 0 UINT_MAX 1 -
Reads the value of the
selected Counter when it
was reset by a trigger or
by an explicit
CounterReset command.
CounterReset@i - - - - Does a software reset of
the selected Counter and
starts it. The counter
starts counting events
immediately after the
reset unless a Counter
trigger is active.
CounterReset can be
used to reset the Counter
independently from the
CounterResetSource. To
21 Appendix A.2 CMOS specific camera / sensor data