Edge of the selected
trigger signal.
AnyEdge: Starts counting
on the Falling or Rising
Edge of the selected
trigger signal.
LevelHigh: Counts as
long as the selected
trigger signal level is
High.
LevelLow: Counts as
long as the selected
trigger signal level is
Low.
TimerDuration 0.000 UINT_MAX - -
Sets the duration (in
microseconds) of the
Timer pulse. (us)
TimerDelay 0.000 UINT_MAX - -
Sets the duration (in
microseconds) of the
delay to apply at the
reception of a trigger
before starting the Timer.
(us)
TimerValue 0.000 UINT_MAX - -
Reads or writes the
current value (in
microseconds) of the
selected Timer. (us)
TimerReset@i - - - -
Does a software reset of
the selected timer and
starts it. The timer starts
immediately after the
reset unless a timer
trigger is active.
Feature Name Min Max Inc
Valid
Values
Documentation
AnalogControl
A category that contains the
Analog control features.
mvTapBalancingMode - - -
mvFactory,
mvUser
States where the tap
balancing calibration data
does come from
mvFactory: States where the
tap balancing calibration data
does come from
mvUser: States where the tap
balancing calibration data
does come from
GainSelector - - -