Reads or writes the
current value (in
microseconds) of the
selected Timer. (us)
TimerReset@i - - - -
Does a software reset of
the selected timer and
starts it. The timer starts
immediately after the
reset unless a timer
trigger is active.
Feature Name Min Max Inc
Valid
Values
Documentation
AnalogControl
A category that contains the
Analog control features.
mvTapBalancingMode - - -
mvFactory,
mvUser
States where the tap
balancing calibration data
does come from
mvFactory: States where the
tap balancing calibration data
does come from
mvUser: States where the tap
balancing calibration data
does come from
GainSelector - - -
AnalogAll,
DigitalAll
Selects which Gain is
controlled by the various Gain
features.
AnalogAll: Gain will be applied
to all analog channels or taps.
DigitalAll: Gain will be applied
to all digital channels or taps.
Gain 0.000 32.000 - -
Controls the selected gain as
an absolute physical value in
dB. This is an amplification
factor applied to the video
signal. (dB)
GainAuto - - -
Off,
Continuous
Sets the automatic gain
control (AGC) mode. The
exact algorithm used to
implement AGC is
device-specific.
Off: Gain is User controlled
using Gain.
Continuous: Gain is constantly
adjusted by the device.
mvGainAutoUpperLimit 0.000 32.000 - -
The upper limit of the gain in
auto gain mode.
mvGainAutoLowerLimit 0.000 32.000 - -
21 Appendix A.2 CMOS specific camera / sensor data
1369

Table of Contents