Sets the frame average
operating mode.
mvNTo1: Sets the frame average
operating mode.
mvFrameAverageFrameCount 2 16 1 -
Here you specify the frame count
used for the calculation of the
frame average.
Feature Name Min Max Inc Valid Values Documentation
LUTControl
A category that includes the LUT control
features.
LUTSelector - - - Luminance
Selects which LUT to control.
Luminance: Selects the Luminance LUT.
LUTEnable - - -
0,
1
Activates the selected LUT.
LUTIndex 0 1023 1 -
Control the index (offset) of the coefficient
to access in the selected LUT.
LUTValue 0 4095 1 -
Returns the Value at entry LUTIndex of
the LUT selected by LUTSelector.
LUTValueAll - - - -
Accesses all the LUT coefficients in a
single access without using individual
LUTIndex.
mvLUTType - - - Direct
Describes the type of LUT used.
Direct: The user can define an output
value for each input value of the LUT.
mvLUTInputData - - - Gray
Describes the data the LUT is operating
on
Gray: The LUT is operating on gray data
mvLUTMapping - - - map_10To12
Describes the mapping of the LUT
map_10To12: The LUT maps 10 bit input
data to 12 bit output data.
Feature Name Min Max Inc
Valid
Values
Documentation
TestControl A category for Test Control features.
TestPendingAck 0 INT_MAX 1 -
Tests the device's pending
acknowledge feature. When this
feature is written, the device waits a
time period corresponding to the
value of TestPendingAck before
acknowledging the write. (ms)
TestEventGenerate@i - - - - Generates a Test Event.