mvLogicGateANDSelector.
Timer2Active: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
Counter1Active: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
Counter2Active: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
Counter3Active: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
Counter4Active: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
mvTemperatureOutOfRange:
Selects the first input signal
of the AND gate selected by
mvLogicGateANDSelector.
mvLogicGateANDSource2 - - - Off,
Line4,
Line5,
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3,
Timer1Active,
Timer2Active,
Counter1Active,
Counter2Active,
Counter3Active,
Counter4Active
This enumeration can be
used to select the second
input signal of the AND gate
selected by
mvLogicGateANDSelector.
Off: Selects the second input
signal of the AND gate
selected by
mvLogicGateANDSelector.
Line4: Selects the second
input signal of the AND gate
selected by
mvLogicGateANDSelector.
Line5: Selects the second
input signal of the AND gate
selected by
mvLogicGateANDSelector.
UserOutput0: Selects the
second input signal of the
AND gate selected by
mvLogicGateANDSelector.
UserOutput1: Selects the
second input signal of the
AND gate selected by
mvLogicGateANDSelector.
UserOutput2: Selects the
second input signal of the
21 Appendix A.2 CMOS specific camera / sensor data
1468