Feature Name Min Max Inc Valid Values Documentation
DigitalIOControl
A category that contains the
digital input and output control
features.
LineSelector - - -
Line0,
Line1,
Line2,
Line3,
Line4,
Line5
Selects the physical line (or pin)
of the external device connector
or the virtual line of the Transport
Layer to configure.
Line0: Index of the physical line
and associated I/O control block
to use.
Line1: Index of the physical line
and associated I/O control block
to use.
Line2: Index of the physical line
and associated I/O control block
to use.
Line3: Index of the physical line
and associated I/O control block
to use.
Line4: Index of the physical line
and associated I/O control block
to use.
Line5: Index of the physical line
and associated I/O control block
to use.
mvLineCaps INT_MIN INT_MAX 1 - Invisible
LineMode - - - Output
Controls if the physical Line is
used to Input or Output a signal.
Output: The selected physical line
is used to Output an electrical
signal.
LineStatus - - -
0,
1
Returns the current status of the
selected input or output Line.
LineSource - - - Off,
ExposureActive,
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3,
Timer1Active,
Timer2Active,
Counter1Active,
Counter2Active,
Counter3Active,
Counter4Active,
AcquisitionActive,
FrameActive,
mvReadOutActive,
Selects which internal acquisition
or I/O source signal to output on
the selected Line. LineMode must
be Output.
Off: Line output is disabled
(Tri-State).
ExposureActive: Device is doing
the exposure of a Frame (or
Line).
UserOutput0: The chosen User
Output Bit state as defined by its
current UserOutputValue.
UserOutput1: The chosen User
Output Bit state as defined by its
current UserOutputValue.
21 Appendix A.2 CMOS specific camera / sensor data