mvLogicGateOR3Output: Selects
which internal acquisition or I/O
source signal to output on the
selected Line.
mvLogicGateOR4Output: Selects
which internal acquisition or I/O
source signal to output on the
selected Line.
mvExposureActive: Selects which
internal acquisition or I/O source
signal to output on the selected
Line.
LineInverter - - -
0,
1
Controls the inversion of the
signal of the selected input or
output Line.
mvLineDebounceTimeRisingEdge 0 5000 1 -
Sets the debounce time in micro
seconds for low to high
transitions.
mvLineDebounceTimeFallingEdge 0 5000 1 -
Sets the debounce time in micro
seconds for high to low
transitions.
LineStatusAll INT_MIN INT_MAX 0x1 -
Returns the current status of all
available Line signals at time of
polling in a single bitfield.
UserOutputSelector - - -
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3
Selects which bit of the User
Output register will be set by
UserOutputValue.
UserOutput0: Selects the bit 0 of
the User Output register.
UserOutput1: Selects the bit 1 of
the User Output register.
UserOutput2: Selects the bit 2 of
the User Output register.
UserOutput3: Selects the bit 3 of
the User Output register.
UserOutputValue - - -
0,
1
Sets the value of the bit selected
by UserOutputSelector.
UserOutputValueAll INT_MIN INT_MAX 0x1 -
Sets the value of all the bits of the
User Output register. It is subject
to the UserOutputValueAllMask.
UserOutputValueAllMask INT_MIN INT_MAX 0x1 - Sets the write mask to apply to
the value specified by
UserOutputValueAll before writing
it in the User Output register. If
the UserOutputValueAllMask
feature is present, setting the user
Output register using
UserOutputValueAll will only
21 Appendix A.2 CMOS specific camera / sensor data