Note:
To get suitable image results, it might be necessary to increase the gain or the illumination.
These settings result in a max. "frame rate" of "2.5 frames per second".
To adjust the opto-mechanics (focus, distance, illumination, etc.), you can use the area mode of the
sensor. That's a main advantage of an area sensor with linescan mode compared to a linescan
camera!
You will need the following pins of the mvBlueFOX3 :
Pin. Signal (Standard version) Description
1 GND Common ground
2 12V .. 24V Power supply
4 Opto DigIn0 (line4)
The output signal A of the
incremental encoder
Setting the application in wxPropView
Summary of our sample:
Property name
wxPropView
Setting
GenICam
Control
Comment
Device Scan Type Linescan Device Control
Height (in pixels) 1000
Image Format
Control
Offset Y (in pixels) 500
Image Format
Control
Exposure Time (in
microseconds)
250.000
Acquisition
Control
Trigger Mode On
Acquisition
Control
Trigger Source Line4
Acquisition
Control
ImageRequestTimeout_ms
(in milliseconds)
0 ms -
This is necessary otherwise there will
be error counts and no frames are
created.
18 Use cases
163