the Counter.
mvLogicGateOR3Output:
Selects the signals that
will be the source to reset
the Counter.
mvLogicGateOR4Output:
Selects the signals that
will be the source to reset
the Counter.
UserOutput0: Resets by
the chosen User Output
bit.
UserOutput1: Resets by
the chosen User Output
bit.
UserOutput2: Resets by
the chosen User Output
bit.
UserOutput3: Resets by
the chosen User Output
bit.
CounterResetActivation - - -
RisingEdge,
FallingEdge,
AnyEdge,
LevelHigh,
LevelLow
Selects the Activation
mode of the Counter
Reset Source signal.
RisingEdge: Resets the
counter on the Rising
Edge of the signal.
FallingEdge: Resets the
counter on the Falling
Edge of the signal.
AnyEdge: Resets the
counter on the Falling or
rising Edge of the
selected signal.
LevelHigh: Resets the
counter as long as the
selected signal level is
High.
LevelLow: Resets the
counter as long as the
selected signal level is
Low.
CounterTriggerSource - - - Off,
AcquisitionStart,
AcquisitionEnd,
FrameStart,
FrameEnd,
ExposureStart,
ExposureEnd,
Line4,
Line5,
Selects the source to
start the Counter.
Off: Disables the Counter
trigger.
AcquisitionStart: Starts
with the reception of the
Acquisition Start.
AcquisitionEnd: Starts
with the reception of the
21 Appendix A.2 CMOS specific camera / sensor data
1785