EasyManuals Logo

Matrix mvBlueFOX3 User Manual

Matrix mvBlueFOX3
1974 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1796 background imageLoading...
Page #1796 background image
CounterReset can be
used to reset the Counter
independently from the
CounterResetSource. To
disable the counter
temporarily, set
CounterEventSource to
Off.
TimerSelector - - -
Timer1,
Timer2
Selects which Timer to
configure.
Timer1: Selects the
Timer 1.
Timer2: Selects the
Timer 2.
TimerTriggerSource - - - Off,
AcquisitionStart,
AcquisitionEnd,
FrameStart,
FrameEnd,
ExposureStart,
ExposureEnd,
Line4,
Line5,
Counter1End,
Counter2End,
Counter3End,
Counter4End,
Timer1End,
Timer2End,
mvLogicGateOR1Output,
mvLogicGateOR2Output,
mvLogicGateOR3Output,
mvLogicGateOR4Output,
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3
Selects the source of the
trigger to start the Timer.
Off: Disables the Timer
trigger.
AcquisitionStart: Starts
with the reception of the
Acquisition Start.
AcquisitionEnd: Starts
with the reception of the
Acquisition End.
FrameStart: Starts with
the reception of the
Frame Start.
FrameEnd: Starts with
the reception of the
Frame End.
ExposureStart: Starts
with the reception of the
Exposure Start.
ExposureEnd: Starts with
the reception of the
Exposure End.
Line4: Starts when the
specified
TimerTriggerActivation
condition is met on the
chosen I/O Line.
Line5: Starts when the
specified
TimerTriggerActivation
condition is met on the
chosen I/O Line.
Counter1End: Starts with
the reception of the
Counter End.
Counter2End: Starts with
the reception of the
21 Appendix A.2 CMOS specific camera / sensor data