CounterReset can be
used to reset the Counter
independently from the
CounterResetSource. To
disable the counter
temporarily, set
CounterEventSource to
Off.
TimerSelector - - -
Timer1,
Timer2
Selects which Timer to
configure.
Timer1: Selects the
Timer 1.
Timer2: Selects the
Timer 2.
TimerTriggerSource - - - Off,
AcquisitionStart,
AcquisitionEnd,
FrameStart,
FrameEnd,
ExposureStart,
ExposureEnd,
Line4,
Line5,
Counter1End,
Counter2End,
Counter3End,
Counter4End,
Timer1End,
Timer2End,
mvLogicGateOR1Output,
mvLogicGateOR2Output,
mvLogicGateOR3Output,
mvLogicGateOR4Output,
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3
Selects the source of the
trigger to start the Timer.
Off: Disables the Timer
trigger.
AcquisitionStart: Starts
with the reception of the
Acquisition Start.
AcquisitionEnd: Starts
with the reception of the
Acquisition End.
FrameStart: Starts with
the reception of the
Frame Start.
FrameEnd: Starts with
the reception of the
Frame End.
ExposureStart: Starts
with the reception of the
Exposure Start.
ExposureEnd: Starts with
the reception of the
Exposure End.
Line4: Starts when the
specified
TimerTriggerActivation
condition is met on the
chosen I/O Line.
Line5: Starts when the
specified
TimerTriggerActivation
condition is met on the
chosen I/O Line.
Counter1End: Starts with
the reception of the
Counter End.
Counter2End: Starts with
the reception of the
21 Appendix A.2 CMOS specific camera / sensor data