mvLogicGateOR2Output,
mvLogicGateOR3Output,
mvLogicGateOR4Output,
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3
ExposureStart: Starts
with the reception of the
Exposure Start.
ExposureEnd: Starts with
the reception of the
Exposure End.
Line4: Starts when the
specified
TimerTriggerActivation
condition is met on the
chosen I/O Line.
Line5: Starts when the
specified
TimerTriggerActivation
condition is met on the
chosen I/O Line.
Counter1End: Starts with
the reception of the
Counter End.
Counter2End: Starts with
the reception of the
Counter End.
Counter3End: Starts with
the reception of the
Counter End.
Counter4End: Starts with
the reception of the
Counter End.
Timer1End: Starts with
the reception of the Timer
End. Note that a timer
can retrigger itself to
achieve a free running
Timer.
Timer2End: Starts with
the reception of the Timer
End. Note that a timer
can retrigger itself to
achieve a free running
Timer.
mvLogicGateOR1Output:
Selects the source of the
trigger to start the Timer.
mvLogicGateOR2Output:
Selects the source of the
trigger to start the Timer.
mvLogicGateOR3Output:
Selects the source of the
trigger to start the Timer.
mvLogicGateOR4Output:
Selects the source of the
trigger to start the Timer.
21 Appendix A.2 CMOS specific camera / sensor data