microseconds) of the
selected Timer. (us)
TimerReset@i - - - -
Does a software reset of
the selected timer and
starts it. The timer starts
immediately after the
reset unless a timer
trigger is active.
Feature Name Min Max Inc
Valid
Values
Documentation
AnalogControl
A category that
contains the Analog
control features.
mvTapBalancingMode - - -
mvFactory,
mvUser
States where the tap
balancing calibration
data does come from
mvFactory: States
where the tap balancing
calibration data does
come from
mvUser: States where
the tap balancing
calibration data does
come from
GainSelector - - - AnalogAll,
DigitalAll,
AnalogTap1,
AnalogTap2,
AnalogTap3,
AnalogTap4,
DigitalTap1,
DigitalTap2,
DigitalTap3,
DigitalTap4
Selects which Gain is
controlled by the
various Gain features.
AnalogAll: Gain will be
applied to all analog
channels or taps.
DigitalAll: Gain will be
applied to all digital
channels or taps.
AnalogTap1: Analog
gain will be applied to
Tap 1.
AnalogTap2: Analog
gain will be applied to
Tap 2.
AnalogTap3: Analog
gain will be applied to
Tap 3.
AnalogTap4: Analog
gain will be applied to
Tap 4.
DigitalTap1: Digital gain
will be applied to Tap 1.
DigitalTap2: Digital gain
will be applied to Tap 2.
21 Appendix A.2 CMOS specific camera / sensor data