Balance(AWB).
mvExposureAutoHeight 0 3288 1 -
Common AOI Height used for Auto
Gain Control(AGC), Auto Exposure
Control(AEC) and Auto White
Balance(AWB).
TriggerSelector - - -
FrameStart,
AcquisitionStart,
AcquisitionEnd,
AcquisitionActive,
mvTimestampReset,
FrameBurstStart,
FrameBurstActive
Selects the type of trigger to
configure.
FrameStart: Selects a trigger starting
the capture of one frame.
AcquisitionStart: Selects a trigger
that starts the Acquisition of one or
many frames according to
AcquisitionMode.
AcquisitionEnd: Selects a trigger that
ends the Acquisition of one or many
frames according to
AcquisitionMode.
AcquisitionActive: Selects a trigger
that controls the duration of the
Acquisition of one or many frames.
The Acquisition is activated when the
trigger signal becomes active and
terminated when it goes back to the
inactive state.
mvTimestampReset: Selects the
type of trigger to configure.
FrameBurstStart: Selects a trigger
starting the capture of the bursts of
frames in an acquisition.
AcquisitionBurstFrameCount controls
the length of each burst unless a
FrameBurstEnd trigger is active. The
total number of frames captured is
also conditioned by
AcquisitionFrameCount if
AcquisitionMode is MultiFrame.
FrameBurstActive: Selects a trigger
controlling the duration of the capture
of the bursts of frames in an
acquisition.
TriggerMode - - -
Off,
On
Controls if the selected trigger is
active.
Off: Disables the selected trigger.
On: Enable the selected trigger.
TriggerSource - - - Line4,
Line5,
Timer1Start,
Timer2Start,
Timer1End,
Timer2End,
Specifies the internal signal or
physical input Line to use as the
trigger source. The selected trigger
must have its TriggerMode set to On.
Line4: Specifies which physical line
(or pin) and associated I/O control
21 Appendix A.2 CMOS specific camera / sensor data