trigger signal.
FallingEdge: Starts
counting on the Falling
Edge of the selected
trigger signal.
AnyEdge: Starts counting
on the Falling or rising
Edge of the selected
trigger signal.
LevelHigh: Counts as
long as the selected
trigger signal level is
High.
LevelLow: Counts as
long as the selected
trigger signal level is
Low.
CounterDuration 0 UINT_MAX 1 -
Sets the duration (or
number of events) before
the CounterEnd event is
generated.
CounterValue 0 UINT_MAX 1 -
Reads or writes the
current value of the
selected Counter.
CounterValueAtReset 0 UINT_MAX 1 -
Reads the value of the
selected Counter when it
was reset by a trigger or
by an explicit
CounterReset command.
CounterReset@i - - - -
Does a software reset of
the selected Counter and
starts it. The counter
starts counting events
immediately after the
reset unless a Counter
trigger is active.
CounterReset can be
used to reset the Counter
independently from the
CounterResetSource. To
disable the counter
temporarily, set
CounterEventSource to
Off.
TimerSelector - - - Timer1,
Timer2
Selects which Timer to
configure.
Timer1: Selects the
Timer 1.
Timer2: Selects the
21 Appendix A.2 CMOS specific camera / sensor data