features to control.
BinningVertical: Selects
which sequencer
features to control.
SequencerFeatureEnable - - -
0,
1
Enables the selected
feature and make it
active in all the
sequencer sets.
SequencerSetStart 0 31 1 -
Sets the initial/start
sequencer set, which is
the first set used within a
sequencer.
SequencerSetSelector 0 31 1 -
Selects the sequencer
set to which further
feature settings applies.
SequencerSetLoad@i - - - -
Loads the sequencer set
selected by
SequencerSetSelector in
the device. Even if
SequencerMode is off,
this will change the
device state to the
configuration of the
selected set.
SequencerSetSave@i - - - -
Saves the current device
state to the sequencer
set selected by the
SequencerSetSelector.
SequencerPathSelector 0 0 1 -
Selects to which
branching path further
path settings applies.
SequencerSetNext 0 31 1 -
Specifies the next
sequencer set.
SequencerTriggerSource - - -
ExposureEnd,
Counter1End
Specifies the internal
signal or physical input
line to use as the
sequencer trigger
source.
ExposureEnd: Starts
with the reception of the
Exposure End.
Counter1End: Starts with
the reception of the
Counter End.
20 Appendix A.1 Pregius CMOS specific camera / sensor data