set selected by the
SequencerSetSelector.
SequencerPathSelector 0 0 1 -
Selects to which
branching path further
path settings applies.
SequencerSetNext 0 31 1 -
Specifies the next
sequencer set.
SequencerTriggerSource - - -
ExposureEnd,
Counter1End
Specifies the internal
signal or physical input
line to use as the
sequencer trigger
source.
ExposureEnd: Starts
with the reception of the
Exposure End.
Counter1End: Starts with
the reception of the
Counter End.
Feature Name Min Max Inc
Valid
Values
Documentation
LUTControl
A category that includes the LUT control
features.
LUTSelector - - - Luminance
Selects which LUT to control.
Luminance: Selects the Luminance LUT.
LUTEnable - - -
0,
1
Activates the selected LUT.
LUTIndex 0 4095 1 -
Control the index (offset) of the coefficient
to access in the selected LUT.
LUTValue 0 511 1 -
Returns the Value at entry LUTIndex of the
LUT selected by LUTSelector.
LUTValueAll - - - -
Accesses all the LUT coefficients in a
single access without using individual
LUTIndex.
mvLUTType - - - Direct
Describes the type of LUT used.
Direct: The user can define an output value
for each input value of the LUT.
mvLUTInputData - - - Gray
Describes the data the LUT is operating on
Gray: The LUT is operating on gray data
mvLUTMapping - - - map_12To9
Describes the mapping of the LUT
map_12To9: The LUT maps 12 bit input
data to 9 bit output data.
20 Appendix A.1 Pregius CMOS specific camera / sensor data