stream channel. This
includes any end-of-line,
end-of-frame statistics or
other stamp data. This is the
total size of data payload for
a data block.
mvU3VPHYErrorCount 0 INT64_MAX 1 -
Counts the number of errors
on the PHY interface.
mvU3VLNKErrorCount 0 INT64_MAX 1 -
Counts the number of errors
on the USB3 link.
Feature Name Min Max Inc
Valid
Values
Documentation
UserSetControl
A category that contains the User Set
control features.
UserSetSelector - - -
Default,
UserSet1,
UserSet2,
UserSet3,
UserSet4
Selects the feature User Set to load,
save or configure.
Default: Selects the factory setting user
set.
UserSet1: Selects the user set 1.
UserSet2: Selects the user set 2.
UserSet3: Selects the user set 3.
UserSet4: Selects the user set 4.
UserSetLoad@i - - - -
Loads the User Set specified by
UserSetSelector to the device and
makes it active.
UserSetSave@i - - - -
Save the User Set specified by
UserSetSelector to the non-volatile
memory of the device.
UserSetDefault - - -
Default,
UserSet1,
UserSet2,
UserSet3,
UserSet4
Selects the feature User Set to load
and make active by default when the
device is reset.
Default: Select the factory setting user
set.
UserSet1: Select the user set 1.
UserSet2: Select the user set 2.
UserSet3: Select the user set 3.
UserSet4: Select the user set 4.
UserSetDefaultSelector - - -
Default,
UserSet1,
UserSet2,
UserSet3,
UserSet4
This feature is deprecated (See
UserSetDefault). Selects the feature
User Set to load and make active when
the device is reset.
Default: Select the factory setting user
set.
UserSet1: Select the user set 1.
UserSet2: Select the user set 2.
UserSet3: Select the user set 3.
UserSet4: Select the user set 4.
20 Appendix A.1 Pregius CMOS specific camera / sensor data