Feature Name Min Max Inc Valid Values Documentation
mvLogicGateControl
Contains features to control
the devices Logic Gate
Control parameters.
mvLogicGateANDSelector - - -
mvLogicGateAND1,
mvLogicGateAND2,
mvLogicGateAND3,
mvLogicGateAND4
This enumeration selects the
AND gate to configure.
mvLogicGateAND1: Selects
the AND gate to configure.
mvLogicGateAND2: Selects
the AND gate to configure.
mvLogicGateAND3: Selects
the AND gate to configure.
mvLogicGateAND4: Selects
the AND gate to configure.
mvLogicGateANDSource1 - - - Off,
Line4,
Line5,
ExposureActive,
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3,
Timer1Active,
Timer2Active,
Counter1Active,
Counter2Active,
Counter3Active,
Counter4Active,
AcquisitionActive,
FrameActive,
LineActive,
FrameTriggerWait,
mvTemperatureOutOfRange
This enumeration can be
used to select the first input
signal of the AND gate
selected by
mvLogicGateANDSelector.
Off: Selects the first input
signal of the AND gate
selected by
mvLogicGateANDSelector.
Line4: Selects the first input
signal of the AND gate
selected by
mvLogicGateANDSelector.
Line5: Selects the first input
signal of the AND gate
selected by
mvLogicGateANDSelector.
ExposureActive: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
UserOutput0: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
UserOutput1: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
UserOutput2: Selects the
first input signal of the AND
gate selected by
mvLogicGateANDSelector.
UserOutput3: Selects the
first input signal of the AND
gate selected by
20 Appendix A.1 Pregius CMOS specific camera / sensor data