AcquisitionMode.
AcquisitionActive: Selects a trigger
that controls the duration of the
Acquisition of one or many frames.
The Acquisition is activated when the
trigger signal becomes active and
terminated when it goes back to the
inactive state.
mvTimestampReset: Selects the
type of trigger to configure.
FrameBurstStart: Selects a trigger
starting the capture of the bursts of
frames in an acquisition.
AcquisitionBurstFrameCount controls
the length of each burst unless a
FrameBurstEnd trigger is active. The
total number of frames captured is
also conditioned by
AcquisitionFrameCount if
AcquisitionMode is MultiFrame.
FrameBurstActive: Selects a trigger
controlling the duration of the capture
of the bursts of frames in an
acquisition.
TriggerMode - - -
Off,
On
Controls if the selected trigger is
active.
Off: Disables the selected trigger.
On: Enable the selected trigger.
TriggerSource - - - Line4,
Line5,
Timer1Start,
Timer2Start,
Timer1End,
Timer2End,
Timer1Active,
Timer2Active,
mvLogicGateOR1Output,
mvLogicGateOR2Output,
mvLogicGateOR3Output,
mvLogicGateOR4Output,
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3,
Counter1End,
Counter2End,
Counter3End,
Counter4End,
Counter1Active,
Counter2Active,
Counter3Active,
Specifies the internal signal or
physical input Line to use as the
trigger source. The selected trigger
must have its TriggerMode set to On.
Line4: Specifies which physical line
(or pin) and associated I/O control
block to use as external source for
the trigger signal.
Line5: Specifies which physical line
(or pin) and associated I/O control
block to use as external source for
the trigger signal.
Timer1Start: Specifies which Timer
signal to use as internal source for
the trigger.
Timer2Start: Specifies which Timer
signal to use as internal source for
the trigger.
Timer1End: Specifies which Timer
signal to use as internal source for
the trigger.
Timer2End: Specifies which Timer
signal to use as internal source for
20 Appendix A.1 Pregius CMOS specific camera / sensor data
671