Counter4Active: Specifies the
internal signal or physical input Line
to use as the trigger source.
Software: Specifies that the trigger
source will be generated by software
using the TriggerSoftware command.
Off: Specifies the internal signal or
physical input Line to use as the
trigger source.
TriggerActivation - - -
LevelHigh,
LevelLow,
mvNone
Specifies the activation mode of the
trigger.
LevelHigh: Specifies that the trigger
is considered valid as long as the
level of the source signal is high.
LevelLow: Specifies that the trigger
is considered valid as long as the
level of the source signal is low.
mvNone: Specifies the activation
mode of the trigger.
TriggerDelay 0.000 UINT_MAX - -
Specifies the delay in microseconds
(us) to apply after the trigger
reception before activating it. (us)
TriggerSoftware@i - - - -
Generates an internal trigger.
TriggerSource must be set to
Software.
mvAcquisitionFrameRateLimitMode - - -
mvDeviceLinkThroughput,
mvDeviceMaxSensorThroughput
Controls the calculation of the
maximum frame rate.
mvDeviceLinkThroughput: Uses the
highest possible frame rate
depending on bandwidth and sensor
settings.
mvDeviceMaxSensorThroughput:
Maximum frame rate the sensor can
provide depending on AOI and pixel
clock. Note: Images might be
buffered in the cameras memory.
This can result in delayed images.
AcquisitionFrameRateEnable - - -
0,
1
Controls if the AcquisitionFrameRate
feature is writable and used to
control the acquisition rate.
Otherwise, the acquisition rate is
implicitly controlled by the
combination of other features like
ExposureTime, etc...
mvAcquisitionFrameRateEnable - - - Off,
On
This feature is deprecated (See
AcquisitionFrameRateEnable). It was
used to enable the
'AcquisitionFrameRate' feature.
Off: The acquisition frame rate is set
20 Appendix A.1 Pregius CMOS specific camera / sensor data
673