Reads or writes the
current value (in
microseconds) of the
selected Timer. (us)
TimerReset@i - - - -
Does a software reset of
the selected timer and
starts it. The timer starts
immediately after the
reset unless a timer
trigger is active.
Feature Name Min Max Inc
Valid
Values
Documentation
AnalogControl
A category that contains
the Analog control
features.
mvTapBalancingMode - - -
mvFactory,
mvUser
States where the tap
balancing calibration
data does come from
mvFactory: States where
the tap balancing
calibration data does
come from
mvUser: States where
the tap balancing
calibration data does
come from
GainSelector - - -
AnalogAll,
DigitalAll
Selects which Gain is
controlled by the various
Gain features.
AnalogAll: Gain will be
applied to all analog
channels or taps.
DigitalAll: Gain will be
applied to all digital
channels or taps.
Gain 0.000 48.000 - -
Controls the selected
gain as an absolute
physical value in dB.
This is an amplification
factor applied to the
video signal. (dB)
GainAuto - - - Off,
Continuous
Sets the automatic gain
control (AGC) mode. The
exact algorithm used to
implement AGC is
device-specific.
Off: Gain is User
controlled using Gain.
20 Appendix A.1 Pregius CMOS specific camera / sensor data