SequencerSetSelector 0 31 1 -
Selects the sequencer
set to which further
feature settings applies.
SequencerSetLoad@i - - - -
Loads the sequencer set
selected by
SequencerSetSelector in
the device. Even if
SequencerMode is off,
this will change the
device state to the
configuration of the
selected set.
SequencerSetSave@i - - - -
Saves the current device
state to the sequencer
set selected by the
SequencerSetSelector.
SequencerPathSelector 0 0 1 -
Selects to which
branching path further
path settings applies.
SequencerSetNext 0 31 1 -
Specifies the next
sequencer set.
SequencerTriggerSource - - -
ExposureEnd,
Counter1End
Specifies the internal
signal or physical input
line to use as the
sequencer trigger
source.
ExposureEnd: Starts
with the reception of the
Exposure End.
Counter1End: Starts with
the reception of the
Counter End.
Feature Name Min Max Inc
Valid
Values
Documentation
LUTControl
A category that includes the LUT control
features.
LUTSelector - - - Luminance
Selects which LUT to control.
Luminance: Selects the Luminance LUT.
LUTEnable - - -
0,
1
Activates the selected LUT.
LUTIndex 0 4095 1 -
Control the index (offset) of the coefficient
to access in the selected LUT.
LUTValue 0 511 1 -
Returns the Value at entry LUTIndex of the
LUT selected by LUTSelector.
LUTValueAll - - - -
20 Appendix A.1 Pregius CMOS specific camera / sensor data
797