horizontal decimation
factor.
DecimationVertical 1 2 1 -
Vertical sub-sampling
of the image. This
reduces the vertical
resolution (height) of
the image by the
specified vertical
decimation factor.
PixelColorFilter - - -
None,
BayerRG,
BayerGB,
BayerGR,
BayerBG
Type of color filter that
is applied to the image.
None: No color filter.
BayerRG: Bayer Red
Green filter.
BayerGB: Bayer Green
Blue filter.
BayerGR: Bayer Green
Red filter.
BayerBG: Bayer Blue
Green filter.
Feature Name Min Max Inc Valid Values Documentation
AcquisitionControl
A category for the acquisition and
trigger control features.
AcquisitionMode - - -
Continuous,
MultiFrame,
SingleFrame
Sets the acquisition mode of the
device. It defines mainly the number
of frames to capture during an
acquisition and the way the
acquisition stops.
Continuous: Frames are captured
continuously until stopped with the
AcquisitionStop command.
MultiFrame: The number of frames
specified by AcquisitionFrameCount
is captured.
SingleFrame: One frame is captured.
ExposureMode - - - Timed,
TriggerWidth
Sets the operation mode of the
Exposure.
Timed: Timed exposure. The
exposure duration time is set using
the ExposureTime or ExposureAuto
features and the exposure starts with
the FrameStart or LineStart.
TriggerWidth: Uses the width of the
current Frame or Line trigger
signal(s) pulse to control the
exposure duration. Note that if the
Frame or Line TriggerActivation is
RisingEdge or LevelHigh, the
20 Appendix A.1 Pregius CMOS specific camera / sensor data