the reception of the Timer
End.
Timer2End: Resets with
the reception of the Timer
End.
mvLogicGateOR1Output:
Selects the signals that
will be the source to reset
the Counter.
mvLogicGateOR2Output:
Selects the signals that
will be the source to reset
the Counter.
mvLogicGateOR3Output:
Selects the signals that
will be the source to reset
the Counter.
mvLogicGateOR4Output:
Selects the signals that
will be the source to reset
the Counter.
UserOutput0: Resets by
the chosen User Output
bit.
UserOutput1: Resets by
the chosen User Output
bit.
UserOutput2: Resets by
the chosen User Output
bit.
UserOutput3: Resets by
the chosen User Output
bit.
CounterResetActivation - - - RisingEdge,
FallingEdge,
AnyEdge,
LevelHigh,
LevelLow
Selects the Activation
mode of the Counter
Reset Source signal.
RisingEdge: Resets the
counter on the Rising
Edge of the signal.
FallingEdge: Resets the
counter on the Falling
Edge of the signal.
AnyEdge: Resets the
counter on the Falling or
rising Edge of the
selected signal.
LevelHigh: Resets the
counter as long as the
selected signal level is
High.
LevelLow: Resets the
counter as long as the
20 Appendix A.1 Pregius CMOS specific camera / sensor data