Counter2End,
Counter3End,
Counter4End,
Timer1End,
Timer2End,
mvLogicGateOR1Output,
mvLogicGateOR2Output,
mvLogicGateOR3Output,
mvLogicGateOR4Output,
UserOutput0,
UserOutput1,
UserOutput2,
UserOutput3
FrameStart: Starts with
the reception of the
Frame Start.
FrameEnd: Starts with
the reception of the
Frame End.
ExposureStart: Starts
with the reception of the
Exposure Start.
ExposureEnd: Starts with
the reception of the
Exposure End.
Line4: Starts when the
specified
TimerTriggerActivation
condition is met on the
chosen I/O Line.
Line5: Starts when the
specified
TimerTriggerActivation
condition is met on the
chosen I/O Line.
Counter1End: Starts with
the reception of the
Counter End.
Counter2End: Starts with
the reception of the
Counter End.
Counter3End: Starts with
the reception of the
Counter End.
Counter4End: Starts with
the reception of the
Counter End.
Timer1End: Starts with
the reception of the Timer
End. Note that a timer
can retrigger itself to
achieve a free running
Timer.
Timer2End: Starts with
the reception of the Timer
End. Note that a timer
can retrigger itself to
achieve a free running
Timer.
mvLogicGateOR1Output:
Selects the source of the
trigger to start the Timer.
mvLogicGateOR2Output:
Selects the source of the
trigger to start the Timer.
20 Appendix A.1 Pregius CMOS specific camera / sensor data