the trigger stays High. If
TriggerActivation is FallingEdge or
LevelLow, the exposure time will last
as long as the trigger stays Low.
ExposureTime 10.000 1000000.000 - -
Sets the Exposure time when
ExposureMode is Timed and
ExposureAuto is Off. This controls
the duration where the
photosensitive cells are exposed to
light. (us)
ExposureAuto - - -
Off,
Continuous
Sets the automatic exposure mode
when ExposureMode is Timed. The
exact algorithm used to implement
this control is device-specific.
Off: Exposure duration is user
controlled using ExposureTime.
Continuous: Exposure duration is
constantly adapted by the device to
maximize the dynamic range.
mvExposureAutoLowerLimit 10.000 1000000.000 - -
The lower limit of the exposure time
in auto exposure mode.
mvExposureAutoUpperLimit 10.000 1000000.000 - -
The upper limit of the exposure time
in auto exposure mode.
mvExposureAutoAverageGrey 0 100 1 -
Common desired average grey value
(in percent) used for Auto Gain
Control(AGC) and Auto Exposure
Control(AEC).
mvExposureAutoHighlightAOI - - -
Off,
On
Highlight auto control AOI to check
AOI settings. Switch off for normal
operation.
Off: Highlight auto control AOI to
check AOI settings. Switch off for
normal operation.
On: Highlight auto control AOI to
check AOI settings. Switch off for
normal operation.
mvExposureAutoAOIMode - - - mvFull,
mvCenter,
mvUser
Common AutoControl AOI used for
Auto Gain Control(AGC), Auto
Exposure Control(AEC) and Auto
White Balancing.
mvFull: Common AutoControl AOI
used for Auto Gain Control(AGC),
Auto Exposure Control(AEC) and
Auto White Balancing.
mvCenter: Common AutoControl AOI
used for Auto Gain Control(AGC),
Auto Exposure Control(AEC) and
Auto White Balancing.
20 Appendix A.1 Pregius CMOS specific camera / sensor data
913