EasyManua.ls Logo

Matrix mvBlueFOX3 - Page 929

Matrix mvBlueFOX3
1974 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Timer2End: Resets with
the reception of the Timer
End.
mvLogicGateOR1Output:
Selects the signals that
will be the source to reset
the Counter.
mvLogicGateOR2Output:
Selects the signals that
will be the source to reset
the Counter.
mvLogicGateOR3Output:
Selects the signals that
will be the source to reset
the Counter.
mvLogicGateOR4Output:
Selects the signals that
will be the source to reset
the Counter.
UserOutput0: Resets by
the chosen User Output
bit.
UserOutput1: Resets by
the chosen User Output
bit.
UserOutput2: Resets by
the chosen User Output
bit.
UserOutput3: Resets by
the chosen User Output
bit.
CounterResetActivation - - -
RisingEdge,
FallingEdge,
AnyEdge,
LevelHigh,
LevelLow
Selects the Activation
mode of the Counter
Reset Source signal.
RisingEdge: Resets the
counter on the Rising
Edge of the signal.
FallingEdge: Resets the
counter on the Falling
Edge of the signal.
AnyEdge: Resets the
counter on the Falling or
rising Edge of the
selected signal.
LevelHigh: Resets the
counter as long as the
selected signal level is
High.
LevelLow: Resets the
counter as long as the
selected signal level is
Low.
20 Appendix A.1 Pregius CMOS specific camera / sensor data
921

Table of Contents