start the Counter.
mvLogicGateOR2Output:
Selects the source to
start the Counter.
mvLogicGateOR3Output:
Selects the source to
start the Counter.
mvLogicGateOR4Output:
Selects the source to
start the Counter.
mvReadOutActive:
Selects the source to
start the Counter.
ExposureActive: Selects
the source to start the
Counter.
CounterTriggerActivation - - -
RisingEdge,
FallingEdge,
AnyEdge,
LevelHigh,
LevelLow
Selects the activation
mode of the trigger to
start the Counter.
RisingEdge: Starts
counting on the Rising
Edge of the selected
trigger signal.
FallingEdge: Starts
counting on the Falling
Edge of the selected
trigger signal.
AnyEdge: Starts counting
on the Falling or rising
Edge of the selected
trigger signal.
LevelHigh: Counts as
long as the selected
trigger signal level is
High.
LevelLow: Counts as
long as the selected
trigger signal level is
Low.
CounterDuration 0 UINT_MAX 1 -
Sets the duration (or
number of events) before
the CounterEnd event is
generated.
CounterValue 0 UINT_MAX 1 -
Reads or writes the
current value of the
selected Counter.
CounterValueAtReset 0 UINT_MAX 1 - Reads the value of the
selected Counter when it
was reset by a trigger or
by an explicit
20 Appendix A.1 Pregius CMOS specific camera / sensor data
923