73
McCONNEL
7.1.5 DRIVE MOTORS
Malfunction
Cause
Solution
Oil leakage from the seals
Strengthening for prolonged storage
Clean the area and check after a few days
Seals damaged or worn
Contact an authorised service centre
Excessive quantity of lubricant
Check the oil level
Excessive vibrations and/or noise
Wheel reduction unit not installed correctly
Contact an authorised service centre
Internal malfunction
Faulty or poorly lubricated bearings
Teeth with dents or chipping
Multiple parking disc brake does not release
Lack of pressure in the braking circuit
Check the connection to the brake
Adhesion of the discs due to parking time
Apply pressure to the brake and turn the
wheel, starting the engine
Faulty brake seals
Contact the service centre
Multiple parking disc brake does not lock
Residual pressure in the circuit
Check the hydraulic circuit
Worn discs
Contact an authorised service centre
With the engine running, the wheel reduction
unit does not turn
Incorrect engine installation
Check the coupling between the engine and
the wheel drive
Brakes locked
Check the braking system
Internal malfunction
Contact an authorised service centre
Wheel reduction unit disengaged
See the DISENGAGEMENT section
Excessive heating
Excessive or insufficient oil
Check the oil level
Unsuitable lubricant
Check the type and status of the lubricant
Faulty or poorly lubricated bearings
Contact an authorised service centre
Multiple disc brake does not open fully
Check the brake opening pressure
High heat outputs
Contact a service centre.