89
McCONNEL
9.5.4 - COOLANT REPLACEMENT
ATTENTION
The coolant must be replaced every 1000 working hours or after 1 year.
Before removing the cap, loosen it slowly until the first stop to relieve the
pressure inside.
The coolant must be chosen very carefully; refer to the table in section 9.4.2.
DANGER
Danger of burns due to very hot coolant!
The cooling system is under pressure! If pressurised coolant spurts out, it
may cause serious injuries.
Before removing the cap, loosen it slowly until the first stop to relieve the
pressure inside.
Remove the fuel filler cap only when it has cooled down enough to be
touched with the bare hand.
When handling fuel or coolant, do not smoke or work near heat sources or
sparks.
DANGER
Dispose of spilled coolant in accordance with the relative standards and do not
allow it to penetrate the ground.
The improper disposal of waste can threaten the environment and the
ecological system. For disposal or correct recycling of waste, contact the
relevant agencies.
The protective agents of the cooling system must be ordered from McConnel
partners.
Never use the engine without coolant, not even for a short time!