CSP-HMI-3MD Helicopters, Inc.
MAINTENANCE MANUAL
[ Main Menu ]
[ HMI−3 Book TOC ]
[ Chapter 96 TOC ]
96-30-00
Page 233
Revision 9
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright © 1999−2016 by MD Helicopters, Inc.
G96-3008
BUS WIRING DIAGRAM
STARTER
GENERATOR
INTERNAL WIRING DIAGRAM
STARTER/GENERATOR
MARATHON CA1700 BATTERY
TEMPERATURE: 75°F (24°C)
INITIAL CHARGE CONDITION:
50%
(DISCHARGE AT
17A. FOR
30 MIN.)
0%
CHARGE TIME (MINUTES)
CURRENT (AMPS)
240
225
210
195
180
165
150
135
120
105
90
75
60
45
30
15
0
010 20 30
40 50 60
GENERATOR
SWITCH
BUS
MASTER
SWITCH
APU
OFF
BATT
BATTER
Y
START
SWITCH
KEY
SWITCH
INTERPOLE COMP.ARMATURE
SERIES
C+ B+ A+ D
E-
RF1 FILTER
SHUNT
FWD
LC
ACFT
LC
GCU
BATT
LC
EXT.
PWR
+
-
J100
APU
LC
START
LC
BATTERY CHARGING DATA
A
B
C
D
E
Figure 211. Bus Wiring Diagram and Battery Charging Data, 500N Helicopters