Table 901. Searchlight Wiring Data List
Wire # From Termination To Termination
P506AE10 BUS − W3−4 MS25036−112 CB127−1 MS25036−153
L557A10 CB127−2 MS25036−156 K302−A1 MS25036−112
Jumper K302−A1 MS25036−102 K303−A1 MS25036−102
Jumper K302−X2 MS25036−102 K303−X2 MS25036−102
Jumper K302−X1 MS25036−102 K303−X1 MS25036−102
Jumper K303−X2 MS25036−102 E27 MS25036−103
* BLACK K303−A2 MS25036−112 DS401−1 MS25036−156
* RED DS401−2 MS25036−112 E27 MS25036−112
* GRAY K303−A2 MS25036−112 DS402−1 MS25036−156
* GREEN DS402−2 MS25036−112 E27 MS25036−112
* L563A16 − (yellow) K302−X1 MS25036−106 S205−2 −
* L564A16 − (yellow) S205−1 − SP66−B 32445
L564B20 SP66−A 32445 CB128−2 MS25036−101
* L510G20 − (white) E27 MS25036−103 S206−1 −
* L562A20 − (white) S206−2 − SP67−B 32445
L562B20 SP67−A 32445 XDS11−2 Solder
Jumper CB128−2 MS25036−101 XDS11−1 Solder
L565A20N XDS11−3 Solder E3 MS25036−101
K510F16 S3−2 MS25036−153 CB128−1 MS25036−153
NOTE: Preferred wire is MIL−W−16878/4. Use the best comparable grade material when the conformity of avail-
able materials of the same type with the listed Specification No. cannot be determined.
* Wires furnished with searchlight assembly.
(6). Using attach screws, attach lower
switch and circuit breaker panel to
instrument panel (Ref. Chap. 95).
H. Searchlight Assembly
For installation of searchlight assembly,
including lamp and lamp assembly, refer to
Installation of Searchlight Assembly.
I. Electrical Wiring
NOTE: Steps a through g provide for wiring in
stallations from the W3 bus to the circuit
breakers, relay terminal K302-A1, caution
light and ground, and splices SP66 and
SP67 (Ref. Figure 202 and Table 901).