CSP-HMI-3 MD Helicopters, Inc.
MAINTENANCE MANUAL
[ Main Menu ]
[ HMI3 Book TOC ]
[ Chapter 95 TOC ]
Page 502
Revision 7
95-00-00
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright © 19992016 by MD Helicopters, Inc.
Table 501. Instrument Cluster ThreePack Calibration Charts
369D26415 Unit (Early Model) (Cont)
Step Remarks
Tolerance
(degrees)
Time
(min)
OhmsGraduation
Engine Oil Temperature
NOTE: Use 0 750 ohm variable resistor across terminal studs 3 and 8.
1 midrange 139 5
215°C 734 ±2 Ascending pointer
3 mid range 139 ±3 Ascending pointer
4 125°C 46.3 ±2 Ascending pointer
WARNING
Comply with applicable electrical safety precautions when checking ammeter
Ammeter
NOTE: Connect variable resistor, test ammeter and ammeter to be tested in series with 14.5 ±0.3 Vdc, 2 ampere
power supply. Variable resistor load must provide current range of 0.75 1.38 amperes for test. Current flow
of 0.75 amperes through ammeter being tested should show 0.75 ampere on test ammeter.
Step Graduation Amperes Tolerance Remarks
1 +0.75 +0.75 ±4
2 -75 to -150 -1.38
300 ±3
NOTE: Without supply voltage applied to cluster, pointer on each ammeter should return to position at or below
lowest calibration mark on ammeter.