Section 5 - Maintenance
90-866938081 MAY 2009 Page 93
a. Insert the molded clip on the aft end of the hatch cover under the indented‑edge
of the cover.
a
c
b
39506
a - Hatch cover
b - Molded clip
c - Indented‑edge
b. Align the access cover with the opening in the top cover.
c. Press down evenly on the front of the access cover. A click‑sound can be heard
when the access cover snaps into final position.
39514
Completing the access cover installation
Filling
If the gear lube level is below the "COLD FILL LEVEL" line, add the specified gear lube.
1. Remove the cap from the gear lube monitor.
a
b
41465
Shown without drive cover
a - Gear lube monitor b - Cap
NOTE: The Premium Gear Lubricant used during the break‑in period is brown in color. The
color of High Performance Gear Lube, used after break‑in, is blue. Do not mix the gear
lubricants.