PAGE 40 Metor 6M
Installation and Operating Manual
8. CALIBRATION 92102916 REV 5
Setting floor level sensitivity
The sensitivity of the equipment at floor level is checked and adjusted separately
when the overall sensitivity of the gate has been adjusted.
After adjusting overall sensitivity, attach the critical test object to the ankle and test
detection by walking through the gate. Walk through the gate for a minimum of
two manners: by placing down the foot with the test object at the middle of the gate
(Fig. 1), and by swinging the foot through the gate (Fig. 2).
If the test object is reliably detected by the gate, repeat the test for the rest of the
test objects. If some test objects are not detected or the sensitivity seems to be too
high at floor level, adjust the floor level sensitivity according to the procedure
below.
1
2