Error message Meaning of the error message Measures
Main
index
Sub
index
39 0 Sercos:
List S-0-0370: invalid
configuration of the MDT Data
container
Please contact the Technical Support.
1 Sercos:
List S-0-0371: invalid
configuration of the AT-Data
container
2 Sercos:
error in the cyclic channel MDT
3 Sercos:
error in the cyclic channel AT
4 Sercos:
error in the cyclic data container
MDT
5 Sercos:
error in the cyclic data container
AT
40 0 Negative SW limit switch
reached
Check the negative range limit.
1 Positive SW limit switch
reached
Check the positive range limit.
2 Target position beyond the
negative SW limit switch
The start of a positioning run has been
suppressed, since the target is located beyond
the respective software limit switch.
Check the target data.
Check the positioning range.
3 Target position beyond the
positive SW limit switch
41 0 Path program: synchronisation
error
Check the parameterization.
If necessary, contact the Technical Support.
42 0 Positioning: no follow-up
position: stop
The positioning target cannot be reached with
the current positioning options or boundary
conditions.
Check the positioning parameters.
1 Positioning: reversal of rotation
not permissible: stop
2 Positioning: reversal of rotation
not permissible after a stop
Product Manual „Servo drives ARS 2100 SE“ Version 5.0

Table of Contents

Other manuals for Metronix ARS 2100 SE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metronix ARS 2100 SE Series and is the answer not in the manual?

Metronix ARS 2100 SE Series Specifications

General IconGeneral
BrandMetronix
ModelARS 2100 SE Series
CategoryServo Drives
LanguageEnglish

Related product manuals