Page 155
Error message Meaning of the error message Measures
Main
index
Sub
index
83 0 Invalid technology module
or
Technology module:
(slot/combination)
Load the correct firmware.
Check the slot.
If necessary, contact the Technical Support.
1 Technology module not
supported
Load the correct firmware.
If necessary, contact the Technical Support.
2 Technology module:
HW revision not supported
3 Service memory module: write
error
Please contact the Technical Support.
4 Technology module:
MC2000 watchdog
84 0 State change of the sequence
control
Detailed information concerning internal
processes.
No measures required. If necessary, select the
option “Entry into buffer” in the error
management.
90 0 Missing hardware component
(SRAM)
Please contact the Technical Support.
1 Missing hardware component
(FLASH)
2 Error during booting of FPGA
3 Error during start of SD-ADUs
4 SD-ADU synchronisation error
after start
5 SD-ADU not synchronous
6 IRQ 0 (current controller):
trigger error
7 CAN controller not available
8 Device parameters checksum
error
9 DEBUG-Firmware loaded
Product Manual „Servo drives ARS 2100 SE“ Version 5.0