EasyManuals Logo

Metronix ARS 2100 SE Series User Manual

Default Icon
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #155 background imageLoading...
Page #155 background image
Page 155
Error message Meaning of the error message Measures
Main
index
Sub
index
83 0 Invalid technology module
or
Technology module:
(slot/combination)
Load the correct firmware.
Check the slot.
If necessary, contact the Technical Support.
1 Technology module not
supported
Load the correct firmware.
If necessary, contact the Technical Support.
2 Technology module:
HW revision not supported
3 Service memory module: write
error
Please contact the Technical Support.
4 Technology module:
MC2000 watchdog
84 0 State change of the sequence
control
Detailed information concerning internal
processes.
No measures required. If necessary, select the
option “Entry into buffer” in the error
management.
90 0 Missing hardware component
(SRAM)
Please contact the Technical Support.
1 Missing hardware component
(FLASH)
2 Error during booting of FPGA
3 Error during start of SD-ADUs
4 SD-ADU synchronisation error
after start
5 SD-ADU not synchronous
6 IRQ 0 (current controller):
trigger error
7 CAN controller not available
8 Device parameters checksum
error
9 DEBUG-Firmware loaded
Product Manual „Servo drives ARS 2100 SE“ Version 5.0

Table of Contents

Other manuals for Metronix ARS 2100 SE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metronix ARS 2100 SE Series and is the answer not in the manual?

Metronix ARS 2100 SE Series Specifications

General IconGeneral
BrandMetronix
ModelARS 2100 SE Series
CategoryServo Drives
LanguageEnglish

Related product manuals