6.2.3 Cleaning Liquid Valve
Work procedures
1. Remove the Front cover M and L.
2. Remove the Ink cartridge.
3. Discharge the cleaning liquid in the tube.
4. Turning the power off.
5. Remove the Fittings (x2).
Remove the Connector.
6. Remove the Valve BKT (Screw x2).
7. Remove the Valve from the Valve BKT.
8. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
Be sure to wear protective glasses and working gloves during the operation.
Cleaning liquid may get into your eyes depending on the working condition, or hand skin may get rough
if you touch the liquid.
Remove cartridge
Fittings
Connector
Other 2 valves are same way
Screws
R.1.0