© 2014 MIMAKI ENGINEERING CO.,LTD. 6.2.10 P.1
1
2
3
4
5
6
7
8
6.2.10 Valve Assy
Work procedures
1. Execute [#ADJUST] — [HEAD WASH] to discharge the ink.
(Refer to 4.2.8)
2. Remove the Cartridge rear cover.
3. Remove snap pin A and then the C link lever.
4. Removes two screws to take off the C valve base together with
the solenoid.
5. Remove the cable connector.
Be sure to wear protective glasses and working gloves during the operation.
Ink may get into your eyes depending on the working condition, or hand skin may get rough if you touch
the ink.
Ink Cartridge Solenoid Assy x8
Valve Assy x8
Snap pin A
C link lever
Screw
C valve base
To connector