4.2.9 MAINT. WASH
Outline
Fill up washing liquid for the sequence to apply it at station maintenance.
Procedure
1. When you perform filling, insert the washing liquid cartridge
into the washing liquid slot.
2. When you discharge, remove it.
3. Select [#ADJUST][MAINT. WASH] from the operation menu.
4. Press the [ENTER] key, and then the valve is released and the
pump rotates.
5. Perform cleaning operation and terminate with [END] key.
FUNCTION
#ADJUST [ENT]
#ADJUST
MAINT. WASH [ENT]
CART:ON END:OFF
EXECUTE [ENT]
PLEASE WAIT
** CLEANING **
PLEASE WAIT