4.2.6 CAPPING
Outline
Adjusts the location for capping. Adjusted value is saved in the system parameter.
Basically, it is not necessary to make adjustment even when cap (and the like) has been replaced.
Adjustment procedure
1. Select [#ADJUST] - [CAPPING].
2. Make adjustment so that the cap slider is located at 3 mm to the
right from the uppermost point it has reached on the cap base.
[]/[]: Horizontally shifts the cap.
[ENTER]: Finalizes (To Next)
3. Make adjustment so that the clearance between the head and
uppermost point of the cap is set at 0.5 mm.
[]/[]: Shifts the cap.
[ENTER]: Finalizes (To Next)
4. Make adjustment so that the clearance between the head and
uppermost point of the cap is set at 1 mm.
[]/[]: Shifts the cap.
[ENTER]: Finalizes (To Next)
FUNCTION
#ADJUST [ENT]
#ADJUST
CAPPING [ENT]
#CAPPING
CAPPING POS= 2.0
3 mm
#CAPPING
AirPullPOS.= 2.0
0.5mm
#CAPPING
FlushingPOS= 2.0
1mm