© 2014 MIMAKI ENGINEERING CO.,LTD. 6.3.5 P.2
6.3.5 Linear Encoder Scale
1
2
3
4
5
6
7
8
5. Remove the screw from the left end of the linear encoder scale,
and detach the Scale holder L and Linear encoder scale
together with the springs.
6. Remove the Linear encoder scale (screw x1).
7. Peel off the left end (the side with short shape hole) of the
protection film on the new Linear encoder scale.
8. Mount the Scale holder L on the Linear encoder scale so that
the surface where the protection film is stuck faces to the Y bar
side.
9. Engage the Scale holder L with the scale base L through a
spring, and mount the Linear encoder scale while peeling off
the protection film.
10. Reverse the disassembly procedure for the subsequent
reassemblies.
Linear encoder scale
Spring
Scale holder L
Scale base L
Linear encoder scale
Spring
Scale holder L
Scale holder L200
While at work, be sure not to attach fingerprints or oil
to the linear encoder scale. Also, pay attention not to
break or scratch it. (If contaminated, clean the scale
with a neutral detergent.)
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Drive System > Linear Encoder Scale
Model
JV300-130/160
Issued
2014.05.30
Revised F/W ver
1.00
Remark
1.0