4- 42 Mx-Series Manual
1. Unplug the machine.
2. Check for dust or foreign materials in the nozzle inserting hole.
If any, remove them with an air gun.
<Precision ANC>
Locking-Unlocking Sensor Check
1. Turn off the servo power of the machine.
2. Turn the sensor on and off while manually moving the cylinder.
3. Check that the sensor works normally.
If no error is found, contact maintenance personnel or Mirae service personnel.
Nozzle inserting hole check
The nozzle inserting hole of ANC needs to be checked regularly.
Check the nozzle inserting hole of ANC as follows.
Nozzle Inserting Hole Nozzle