5-24 Mx-Series Manual
11401
Upper line inspection
error (Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
11402
Lower line inspection
error (Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
11403
Left line detection
error (Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
11404
Right line inspection
error (Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
11410
Line detection angle
error (Up-Left)
(Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
11411
Line detection angle
error (Up-Right)
(Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
11412
Line detection angle
error (Up-Down)
(Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
11413
Line detection angle
error (Down-Left)
(Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
11414
Line detection angle
error (Down-Right)
(Centering)
Check illumination, contamination of
component and background and
component DB information and retry
inspection.
Error Code
Message Description
Actions
References
12000
Nozzle is stained with
foreign materials or chip is
detected at the nozzle after
placement.
Check the nozzle.
Carry out cleaning and
maintenance referring to the
nozzle check procedure.
12001
TF rack pallet alignment
error
Align the tray feeder pallet.
12002
Mark detection error
Check the location and status of
the Fiducial Mark.
12003
Offset jig ejection error
12004
Axial motion stopped due to
door open
Close the door.
5-27
12005
The nozzle is incorrect.
Replace the nozzle with a
correct one.
Check the nozzle.
Check the nozzle setting of ANC.