Installation
40
Module Placement
Note that the placement of modules is as shown in the table below. Figure 24 below shows the placement of the
paging & telephone modules.
Figure 24: Lobby Enclosure Module Placement
Firefighter’s Telephone
For the firefighter's telephone, the QMT-5300A may be used alone for a single zone system. For a multi-zone
system, the P1 ribbon cable on the first QZT-5302 Telephone Selector panel connects down to the P1 socket on the
QMT-5300A. Each successive QZT-5302's P1 ribbon cable plugs down into the P2 connector on the previous QZT-
5302. The QMT-5300A is also wired either directly to a fire alarm control panel if used alone, or to the emergency
paging system's QMP-5100B if used together.
Emergency Paging System
For the emergency paging system, the P1 ribbon cable on the first QZP-5101 Paging Selector panel connects down
to the P3 socket on the QMP-5100B. Each successive QZP-5101's P1 ribbon cable plugs down into the P2
connector on the previous QZP-5101.The QMP-5100B is also wired to the QIF-5000B in the audio cabinet, and to
the QMT-5300A (if used).
Firefighter’s Telephone
(up to six zone adders
allowed)
Emergency Paging
(up to five zone adders
allowed)
In large
enclosure
(contact factory)
Top
QZT-5302 Zone Adder Module QZP-5101 Zone Adder Module
QZT-5302 Zone Adder Module QZP-5101 Zone Adder Module
QZT-5302 Zone Adder Module QZP-5101 Zone Adder Module
QZT-5302 Zone Adder Module QZP-5101 Zone Adder Module
In BB-1000
Enclosure
QZT-5302 Zone Adder Module QZP-5101 Zone Adder Module
QZT-5302 Zone Adder Module QZP-5101 Zone Adder Module
Bottom QMT-5300A Master Module QMP-5100B Master Module
C
OMMO
N
TEL.
T
R
O
UB
LE
L
A
MP
TEST
I
NC
OMI
N
G
CA
LL
M
A
STE
R
TEL.
T
R
O
UB
LE
C
O
NN
E
C
T/
C
LE
AR
A
LL
R
E
M
OTE
ANNUNC
I
A
TO
R
P
A
GE
#1
P
A
GE
#2
P
A
GE
#4
P
A
GE
#3
P
A
GE
#5
P
A
GE
#6
P
A
GE
#8
P
A
GE
#7
P
A
GE
#9
P
A
GE
#10
P
A
GE
#12
P
A
GE
#11
P
A
GE
#17
P
A
GE
#18
P
A
GE
#20
P
A
GE
#19
P
A
GE
#13
P
A
GE
#14
P
A
GE
#16
P
A
GE
#15
P
A
GE
#21
P
A
GE
#22
P
A
GE
#24
P
A
GE
#23
R
E
M
OTE
ANNUNC
I
A
TO
R
TELEP
H
O
N
E
#7
TELEP
H
O
N
E
#5
TELEP
H
O
N
E
#9
TELEP
H
O
N
E
#11
TELEP
H
O
N
E
#1
TELEP
H
O
N
E
#2
TELEP
H
O
N
E
#4
TELEP
H
O
N
E
#3
TELEP
H
O
N
E
#10
TELEP
H
O
N
E
#6
TELEP
H
O
N
E
#8
TELEP
H
O
N
E
#12
TELEP
H
O
N
E
#7
TELEP
H
O
N
E
#5
TELEP
H
O
N
E
#9
TELEP
H
O
N
E
#11
TELEP
H
O
N
E
#1
TELEP
H
O
N
E
#2
TELEP
H
O
N
E
#4
TELEP
H
O
N
E
#3
TELEP
H
O
N
E
#10
TELEP
H
O
N
E
#6
TELEP
H
O
N
E
#8
TELEP
H
O
N
E
#12
P
A
GE
#25
P
A
GE
#26
P
A
GE
#28
P
A
GE
#27
P
A
GE
#29
P
A
GE
#30
P
A
GE
#32
P
A
GE
#31
P
A
GE
#33
P
A
GE
#34
P
A
GE
#36
P
A
GE
#35
P
A
GE
#41
P
A
GE
#42
P
A
GE
#46
P
A
GE
#45
P
A
GE
#37
P
A
GE
#38
P
A
GE
#40
P
A
GE
#39
P
A
GE
#45
P
A
GE
#46
P
A
GE
#48
P
A
GE
#47

Table of Contents

Other manuals for Mircom QX-5000 Series

Related product manuals