Access Criteria
TX3 Nano Configuration Manual 71
Copyright 2019
The common trouble status clears only if all the above inputs are back in normal
state.
9.4.2 Common alarm
The common alarm status is active when any of the following inputs receive an
alarm condition:
• forced entry alarm
• door held open alarm
The common alarm status clears only if all the above inputs are back in normal
state.
9.4.3 Tamper alarm
The TX3 Nano has a tamper feature. If it is powered on and not mounted on the
mounting plate, a tone sounds. The tone stops sounding when it is mounted. The
TX3 Nano does not operate until the tamper alarm is restored.