2.9.6 Network Modules for CC-Link
CC-Link Master Module FX2N-16CCL-M
The CC-Link network enables the controlling and monitoring of decentralized I/O modules at the
machine.
The CC-Link master module FX2N-16CCL-M is a special extension block which assigns an FX
series PLC as the master station of the CC-Link system.
CC-Link Communication Modules FX
2N-32CCL and FX3U-64CCL
The communication modules FX
2N-32CCL and FX3U-64CCL enable the user to connect to the
CC-Link network with a superior PLC system as master CPU. This gives him access to the net-
work of all MELSEC PLC systems and frequency inverters and to additional products from other
suppliers.
Overview of Network Modules for CC-Link
쎲
The special function module can be used with a base unit or expansion unit of this series.
쑗
The special function module cannot be used with this series.
Extending for Special Functions The Hardware
2-28 MITSUBISHI ELECTRIC
FX -16CCL-M
2n
CC-
LINK
RUN
ERR.
MST
TEST 1
TEST 2
L RUN
L ERR.
SW
M/S
PRM
TIME
LINE
SD
RD
The setting of all modules within the network
is handled directly via the master module.
Up to 15 remote stations (7 remote I/O sta
-
tions and up to 8 remote device stations) can
be connected to the master station. Two mas
-
ter modules can be connected to one base
unit.
The maximum communications distance is
1200 m without repeater.
LRUN•LERR•RD•SD
FX -32CCL2N
Thus the network is expandable via the digital
inputs/outputs of the FX modules to a maxi-
mum of 256 I/Os.
Module type Designation Description FX1S FX1N
FX2N
FX2NC
FX3G
FX3U
FX3UC
Special function modules
FX
2N-16CCL-M Master for CC-Link
쑗쎲쎲쎲쎲
FX
2N-32CCL
Remote device station
for CC-Link
쑗쎲쎲쎲쎲
FX
3U-64CCL
쑗쑗쑗쎲쎲