EasyManua.ls Logo

Mitsubishi Electric M800VS Series - Page 558

Mitsubishi Electric M800VS Series
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M800VS/M80V Series Connection and Setup Manual
29 Deceleration Check
29.4 Parameters
527
IB-1501613-A
Designating in-position check width
[Servo parameters]
[Axis specification parameters]
# Item Description Setting range
2224 SV024 INP
In-position detection width Set the in-position detection width.
Set the positioning accuracy required for the machine.
The lower the setting is, the higher the positioning accuracy gets;
however, the cycle time (setting time) becomes longer.
The standard setting value is "50".
0 to 32767
(μm)
13024 SP024 INP
In-position detection width Set the in-position detection width.
Set the positioning accuracy required for the machine.
The lower the setting is, the higher the positioning accuracy gets;
however, the cycle time (setting time) becomes longer.
The standard setting value is "875".
0 to 32767
(1°/1000)
# Item Description Setting range
2077 G0inps
G0 in-position width Set the in-position width for G0.
Between SV024 and this parameter, the parameter with a larger
value will be applied.
When set as "0", this parameter will be invalid: only SV024 will
be available.
0.000 to 99.999
(mm)
2078 G1inps
G1 in-position width Set the in-position width for G1.
Between SV024 and this parameter, the parameter with a larger
value will be applied.
When set as "0", this parameter will be invalid: only SV024 will
be available.
0.000 to 99.999
(mm)