M800VS/M80V Series Connection and Setup Manual
23 Setting the Tool Entry Prohibited Range
23.2 Stored Stroke Limit
473
IB-1501613-A
23.2.5 Stored Stroke Limit IC
Boundaries are set for each axis with the axis parameters "#2061 OT_1B-" and "#2062 OT_1B+". The inside of the set
boundary is the machine movement valid range.
Stored stroke limit IC is valid when the axis parameter "#2063 OT_1Btype (Soft limit IB type)" is set to "2". Cannot be used
with soft limit IB.
: Moveable range
: Prohibited range
Positions No. 3 "#2062 OT_1B+ (Soft limit IB+)" and No. 4 "#2061 OT_1B- (Soft limit IB-)" are set using coordinates from the
basic machine coordinate system.
Positions No. 1 and 2 define the prohibited range as set with stored stroke limit I.